1428 Maple Hollow Lane

For Sam, 12-page report, sample inspection.

Home photo

No photo yet, so buyers see a simple house drawing instead.

Overall condition your buyer sees
Solid overall, with a few priorities

Every home has a list. Most of these are routine.

Overview your buyer sees

This is a well-kept home with mostly routine upkeep items. The main priorities are lowering the radon level, adding a safety pipe to the water heater, fixing a doubled-up breaker, and adding a carbon monoxide detector upstairs. The furnace and AC are older and due for service, so it’s worth budgeting for them.

Your buyer asked for repair quotes

We’re connecting them with local pros. Nothing for you to do. This is just so you’re in the loop.

Yesterday · Sam · closing in about 3 weeks
Radon, Plumbing: 2 items. Radon level above the EPA action level; Water heater is missing its safety discharge pipe
✓ Shared with your buyer
Shared 2 days ago · opened 3 times, last today
Send it to your buyer
Your buyer sees this first, with your name. Changes show up as soon as you save.
Stops the link working right away.
Your buyer sees every finding as written. Add a note, or report a problem and we’ll fix it.
01

Before closing

High4 items
Preview of page 12 of the inspection report Page 12Click to open this page in the report
Safety

Radon level above the EPA action level

The 48-hour radon test averaged 5.2, above the 4.0 level where the EPA recommends a fix. This is common and very fixable.

Why it matters
Long-term exposure to radon, a natural radioactive gas, raises lung cancer risk.
Next step
Get a quote from a certified radon mitigation contractor. A typical system is installed in a day.
What the inspector wrote

Average radon concentration of 5.2 pCi/L; the EPA action level is 4.0 pCi/L. Mitigation is recommended.

Your note, shown to your buyer
Very common in this area. I’ll ask the seller to cover mitigation as part of our repair request.
Preview of page 5 of the inspection report Page 5Click to open this page in the report
Plumbing

Water heater is missing its safety discharge pipe

The water heater’s pressure-relief valve has no pipe to direct hot water safely to the floor. The heater is also about 14 years old.

Why it matters
Without the pipe, a valve release could spray scalding water. At this age, the heater may need replacing soon.
Next step
Have a plumber add the discharge pipe and a catch pan, and price a replacement while they’re there.
What the inspector wrote

TPR valve discharge pipe missing; no catch pan; unit approx. 14 years old, near end of typical service life.

Preview of page 8 of the inspection report Page 8Click to open this page in the report
Electrical

Double-tapped breaker in the main panel

Two wires share a breaker that’s made for one. It’s a quick fix for an electrician.

Why it matters
A loose connection can overheat and become a fire risk.
Next step
Have a licensed electrician correct it. Ask them to add GFCI outlets at the same visit.
What the inspector wrote

A double-tapped breaker was observed (two wires on a breaker designed for one).

Preview of page 9 of the inspection report Page 9Click to open this page in the report
Safety

No carbon monoxide detector near the bedrooms

There’s no carbon monoxide detector near the upstairs bedrooms. Detectors are inexpensive and easy to add.

Why it matters
Carbon monoxide is odorless; detectors near sleeping areas are the main warning.
Next step
Install CO detectors on each level and near the bedrooms before move-in.
What the inspector wrote

No CO detector present near the upstairs bedrooms.

02

In the first year

Moderate11 items
Preview of page 8 of the inspection report Page 8Click to open this page in the report
Electrical

Kitchen and bathroom outlets need GFCI protection

The outlets near water in the kitchen and main bath don’t have the shock-protection type now standard in wet areas.

Why it matters
GFCI outlets cut power instantly if water causes a short, preventing shocks.
Next step
An electrician can swap these in an hour or two.
What the inspector wrote

Kitchen countertop outlets and the main bathroom outlet were not GFCI protected.

Preview of page 6 of the inspection report Page 6Click to open this page in the report
Heating & Cooling

Furnace is due for cleaning and service

The furnace works, but it’s dusty and the filter is very dirty. An HVAC tech should clean it and check the parts the inspector couldn’t see.

Why it matters
Regular service keeps a furnace running safely and efficiently.
Next step
Schedule a furnace service and inspection, ideally before your objection deadline.
What the inspector wrote

Very dirty filter; dust in burner compartment; heat exchanger not fully visible. Recommend HVAC evaluation.

Preview of page 7 of the inspection report Page 7Click to open this page in the report
Heating & Cooling

Older AC unit due for service

The outdoor AC unit is from 2008 and uses an older refrigerant that’s expensive to refill. It works, but plan for a replacement in the next few years.

Why it matters
Older units cost more to repair and run, so budgeting ahead avoids surprises.
Next step
Have it cleaned and serviced, and get a replacement estimate for planning.
What the inspector wrote

Condenser fins dirty and bent; refrigerant line insulation missing; 2008 unit using R-22, may be near end of life.

Preview of page 4 of the inspection report Page 4Click to open this page in the report
Roofing

A few shingles lifted or missing

A small area of the roof has lifted shingles and two missing ones. A roofer can patch this.

Why it matters
Gaps in shingles can let water in during storms.
Next step
Have a roofer repair the south slope and check the rest of the roof.
What the inspector wrote

Several shingles lifted and two missing on the south-facing slope.

Preview of page 11 of the inspection report Page 11Click to open this page in the report
Plumbing

Loose tile and worn caulk in the upstairs shower

A few shower tiles are loose and the caulk is worn. Re-securing and re-caulking keeps water out of the walls.

Why it matters
Water behind tile can cause hidden damage over time.
Next step
Have a handyman or tile pro re-set the loose tiles and re-caulk.
What the inspector wrote

Loose tile and deteriorated caulking at the shower surround.

Preview of page 10 of the inspection report Page 10Click to open this page in the report
Appliances

Dishwasher leaks at the door seal

The dishwasher leaked a little at the door seal when it ran. Usually the gasket just needs replacing.

Why it matters
Small leaks can damage flooring and cabinets over time.
Next step
Have an appliance tech replace the door gasket.
What the inspector wrote

Dishwasher leaked at the lower door seal during operation.

Preview of page 10 of the inspection report Page 10Click to open this page in the report
Safety

Range is missing an anti-tip bracket

The stove isn’t anchored with the small bracket that keeps it from tipping if someone leans on the open door.

Why it matters
Tip-overs are a known hazard, especially for children.
Next step
Install an anti-tip bracket. It’s a quick, inexpensive fix.
What the inspector wrote

Range not secured with an anti-tip bracket; tip-over hazard.

Preview of page 9 of the inspection report Page 9Click to open this page in the report
Interior

Some windows have loose tracks and broken locks

A few windows have loose tracks, two have broken locks, and some screens are damaged.

Why it matters
Working locks matter for security, and smooth tracks keep windows easy to open.
Next step
A handyman can repair the tracks and replace the locks and screens.
What the inspector wrote

Loose tracks at three windows; broken locks at living room and rear bedroom windows; damaged screens.

Preview of page 9 of the inspection report Page 9Click to open this page in the report
Safety

Stair railing gaps are wide for small children

The gaps in the stair railing are wider than today’s 4-inch guideline, which matters if small children will live here.

Why it matters
Small children can slip through or get stuck in wide gaps.
Next step
Add balusters or a railing guard if you have young kids.
What the inspector wrote

Stair railing baluster openings exceeded 4 inches.

Preview of page 3 of the inspection report Page 3Click to open this page in the report
Exterior

Downspout drains next to the foundation

One downspout at the back has come loose and empties right next to the house.

Why it matters
Water pooling by the foundation is the most common cause of basement moisture.
Next step
Reconnect it and add an extension so water lands 4–6 feet away.
What the inspector wrote

Rear left downspout disconnected, discharging next to the foundation.

Preview of page 3 of the inspection report Page 3Click to open this page in the report
Exterior

Soft trim at the garage door frame

Some wood trim at the bottom of the garage door frame is soft and needs replacing.

Why it matters
Rotted trim lets in moisture and pests if left alone.
Next step
Have a handyman replace and seal the damaged trim.
What the inspector wrote

Deteriorated wood at the lower garage door frame trim.

03

Routine upkeep

Low5 items
Preview of page 3 of the inspection report Page 3Click to open this page in the report
Exterior

Small crack in the front walkway

There’s a small settling crack in the front walkway. It’s cosmetic for now.

Why it matters
Sealing it keeps water from widening the crack over winters.
Next step
Seal the crack and keep an eye on it.
What the inspector wrote

Settlement crack approx. 1/4 inch in front walkway.

Preview of page 4 of the inspection report Page 4Click to open this page in the report
Roofing

Attic insulation is uneven

The attic insulation is thin in spots. Adding more is an easy energy upgrade.

Why it matters
Better insulation lowers heating and cooling bills.
Next step
Consider topping up the insulation after move-in.
What the inspector wrote

Insulation unevenly distributed, approx. 6 inches deep in places.

Preview of page 5 of the inspection report Page 5Click to open this page in the report
Plumbing

Upstairs bathroom sink drains slowly

The upstairs bathroom sink drains slowly, usually a simple clog.

Why it matters
Clearing it now prevents a full blockage later.
Next step
Clean the drain or have a plumber clear it.
What the inspector wrote

Upstairs bathroom sink slow to drain.

Preview of page 11 of the inspection report Page 11Click to open this page in the report
Plumbing

Upstairs toilet runs on and off

The upstairs toilet runs now and then. A new flapper or fill valve usually fixes it.

Why it matters
A running toilet wastes water and raises the bill.
Next step
Replace the flapper or fill valve, an inexpensive part.
What the inspector wrote

Toilet ran intermittently.

Preview of page 9 of the inspection report Page 9Click to open this page in the report
Interior

Have the fireplace cleaned before first use

Before your first fire, have a chimney sweep clean and check the fireplace. This is routine for any home.

Why it matters
Built-up soot can catch fire, and a sweep checks that the chimney is clear.
Next step
Book a chimney sweep before you use the fireplace.
What the inspector wrote

Firebox and chimney should be cleaned and inspected before use.

Your first report takes about two minutes.

Upload the inspector’s PDF, look it over, and share one link. Free for agents.